LED power supply lightning arrester HD-LED10B

    Online Inquiry
    Click Refresh Verification Code

    Details

    This product is used for the LED lamps and lanterns of protection and lightning surge pulse.Due to the LED lamps and lanterns for the core of the device is a semiconductor diode,ability is extremely low,even overvoltage,5-6V is enough to destroy the light bead,so you need to select special lightning protection device for the LED power supply lines to surge overvoltage protection,avoid large area caused by lighting strike the same region,the situation of the LED lamps and the lanterns of the black light,the company developed product has the following characteristics :

    1. There are two structuresin parallel and in series.series connection type timely diagnose working state of the lightning protection and change in time so as not to cause secondary lightning lamps;

    2. For big surge of absorptive capacity,low output residual voltage,compact appearance,optional water-proof structure,easy installation.


    Model

    HD-LED10B

    Certification

    CEULCBROSH

    Nominal working voltage Un

    110-277V

    Maximum continuous working voltage Uc

    320V

    Withstand impact voltage

    10KV

    Nominal discharge current In8/20μs

    5KA

    Maximum discharging current Imax8/20μs

    10KA

    Voltage protection level Up


    3KV

    6KV

    Uoc

    In

    N-LKV

    1.2

    1.2

    1.2

    1.5

    L-PEKV

    1.2

    1.2

    1.2

    1.5

    N-PEKV

    1.5

    1.5

    1.5

    1.5

    Drain currrent Ir

    5μA

    Response time Ta

    25ns

    Operating temperature range Tup

    -40℃至+70

    Protection grade

    IP67

    Sheathing material

    Vo fire-proof engineering plastic

    Mode of connection

    In parallel

    Interface mode

    Terminal

    External dimension

    62*35*22mm

    Fault indication

    No




    1.When the voltage parameters of the protector does not match the equipment operating parameter,it may affect the work of circuit. It is recommended to determine the device operating voltage when selecting.

    2. Plug the power phase line (L) and null line (N)into corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection appropriately (recommended earth resistance 4Ω).